Skip to content
GRIDSPEC
Verified Engineering Spec • NEC 2026 / UL 9540

Can the Anker SOLIX F2000 (PowerHouse 767) Run a 15,000 BTU RV Rooftop Air Conditioner (Dometic/Coleman)?

Live runtime simulator, solar recharge calculator and NEC / IEC breaker & cable schematic for the Anker SOLIX F2000 (PowerHouse 767) (2,048 Wh) paired with the 15,000 BTU RV Rooftop Air Conditioner (Dometic/Coleman).

Configure your system

800 W
25 ft (7.6 m)
65%
Source outlets
NEMA TT-30R / 5-20R
Load connection
NEMA TT-30P
Verified Hardware Match

Check current bundle pricing for the Anker SOLIX F2000 (PowerHouse 767) plus a transfer switch kit for this setup.

As an Amazon Associate, we earn from qualifying purchases.

Verified Compatible

Anker SOLIX F2000 (PowerHouse 767) handles 1,650 W continuous and 3,600 W surge with headroom.

750 W of continuous capacity left for other circuits.

Continuous load
69%
Runtime (no sun)
1.6 hrs
65% duty · 85% inverter eff.
Solar recharge
3.2 hrs
0.7 sun-days at 800 W
Min. copper wire
12 AWG
1.1% drop @ 25 ft
Overcurrent device
20A Breaker
13.8A load × 1.25 = 17.2A
Live schematic & breaker sizing diagram 120V AC • NEC 125% Rule
SOLAR PV INPUT 800 W PV MC4 / XT60 · MPPT POWER SOURCE / INVERTER Anker SOLIX F2000 (PowerHouse 767) 2,048 Wh • 2,400 W 3,600 W surge • 120V 69% load 20A OCPD 12 AWG Cu 13.8A @ 120V CONNECTED LOAD 15,000 BTU RV Rooftop Air Conditioner (Dome… 1,650 W running 3,600 W surge 120V load

Engineering report · reviewed against NEC 2026 & BS 7671:2018+A2

Engineering Breakdown: Running a 15,000 BTU RV Rooftop Air Conditioner (Dometic/Coleman) on the Anker SOLIX F2000 (PowerHouse 767)

US/NA: Verified Compatible UK/EU/AU: Verified Compatible 69% inverter utilization

When pairing the Anker SOLIX F2000 (PowerHouse 767) (2,048 Wh LiFePO4 capacity, 2,400 W continuous, 3,600 W surge) with a 15,000 BTU RV Rooftop Air Conditioner (Dometic/Coleman) (1,650 W running, 3,600 W starting surge), the system operates at 69% of continuous inverter capacity on a 120 V North American circuit and 69% on a 230 V UK/EU/AU circuit. At a 100% duty cycle and 85% inverter efficiency, a full battery delivers roughly 1.1 hrs of off-grid runtime. Wiring the connection over a 25 ft run calls for a 20 A breaker and 12 AWG copper, terminated at a NEMA TT-30P connection.

1. Compatibility Verdict & Inverter Load Utilization

In North American mode the 15,000 BTU RV Rooftop Air Conditioner (Dometic/Coleman) loads the Anker SOLIX F2000 (PowerHouse 767)'s inverter to 69% of its 2,400 W continuous rating and 100% of its 3,600 W surge rating. Both figures are under the 80% sustained-load guideline, so this is a comfortable, verified match with 750 W of spare capacity for lights, a router or a refrigerator on the same unit.

CheckLoad requiresAnker SOLIX F2000 providesUS/NAUK/EU/AU
Continuous output 1,650 W 2,400 W Pass Pass
Start-up surge 3,600 W 3,600 W Pass Pass
Voltage 120 V / 230 V 120 V / 230 V Pass Pass
Connection NEMA TT-30P NEMA TT-30R / 5-20R UK/EU/AU: BS 1363 13A / Schuko CEE 7/4 / AS/NZS 3112 10A

RV rooftop air conditioners are designed for 30 A, 120 V shore power (NEMA TT-30), so they are a natural match for portable power stations — provided the inverter can absorb the compressor start. This unit's 3,600 W start-up spike is 2.2× its running draw. Against the Anker SOLIX F2000 (PowerHouse 767)'s 3,600 W surge rating that leaves 0 W of margin. Boondockers should plan around overnight runtime: shading the coach, using the fan-only mode and setting the thermostat 2–3 °F higher can halve the duty cycle.

As a portable power station, the Anker SOLIX F2000 (PowerHouse 767) integrates the LiFePO4 battery, inverter, MPPT solar controller and AC outlets in one chassis, so it can be wheeled to the load or connected to a transfer switch through its NEMA TT-30R / 5-20R outlet.

2. Real-World Runtime by Duty Cycle

Nameplate capacity is not usable capacity. DC-to-AC conversion, battery management overhead and cell protection reduce the 2,048 Wh rating to about 1,741 Wh of deliverable AC energy (85% system efficiency). Duty cycle is the share of each hour the load actually draws its running power — thermostats, pressure switches and intermittent use all lower it.

Runtime (h) = (2,048 Wh × 0.85) ÷ (1,650 W × duty cycle)
Duty cycleAverage drawRuntime (no solar)Energy per 24 h
25% 413 W 4.2 hrs 9.9 kWh
50% 825 W 2.1 hrs 19.8 kWh
65% 1,073 W 1.6 hrs 25.7 kWh
100% 1,650 W 1.1 hrs 39.6 kWh

Even at a 50% duty cycle the battery lasts 2.1 hrs, so plan on solar, grid or generator recharging for anything longer than an evening outage.

3. NEC 125% Breaker & Copper Wire Gauge Sizing

NEC 210.19(A) and 210.20(A) require conductors and overcurrent devices for continuous loads — anything running three hours or more, which includes EV charging and HVAC — to be rated at 125% of the load current. For this pairing: 1,650 W ÷ 120 V = 13.8 A, × 1.25 = 17.2 A, which rounds up to the next standard NEC 240.6 size of 20 A. The conductor must be protected by that breaker (75 °C ampacity at least 20 A) and keep round-trip voltage drop at or below 3%, so longer runs are upsized.

Breaker ≥ (1,650 W ÷ 120 V) × 1.25 = 17.2 A → 20 A
Voltage drop % = (2 × L × I × R) ÷ V × 100

North America (NEC, THHN copper, 75 °C)

One-way distanceBreakerMin. copperVoltage dropNote
25 ft (7.6 m) 20 A 12 AWG 1.11% Sized by ampacity
50 ft (15.2 m) 20 A 12 AWG 2.21% Sized by ampacity
75 ft (22.9 m) 20 A 10 AWG 2.08% Upsized for voltage drop
100 ft (30.5 m) 20 A 10 AWG 2.77% Upsized for voltage drop

UK / EU / Australia (IEC 60364 / BS 7671, PVC copper, method C)

IEC-based codes size protection by design current rather than a blanket 125% multiplier: Ib ≤ In ≤ Iz. At 230 V the load draws 7.2 A, so a 10 A Type B/C MCB with RCD protection applies. In the UK, BS 7671 Section 722 additionally requires a dedicated circuit and Type A or Type B RCD for EV charge points.

One-way distanceMCBMin. cableVoltage drop
7.5 m (25 ft) 10 A 1.5 mm² 0.57%
15 m (49 ft) 10 A 1.5 mm² 1.13%
22.5 m (74 ft) 10 A 1.5 mm² 1.70%
30 m (98 ft) 10 A 1.5 mm² 2.26%

Moving the Anker SOLIX F2000 (PowerHouse 767) from 25 ft to 100 ft away forces the conductor up from 12 AWG to 10 AWG — park the unit as close to the load as ventilation and weather protection allow.

4. Solar Array Recharge Time Breakdown

The Anker SOLIX F2000 (PowerHouse 767) accepts up to 1,000 W of photovoltaic input. Real arrays rarely deliver nameplate output, so we apply an 80% harvest factor for MPPT conversion, cell temperature and soiling, and convert hours to days using 4.5 peak-sun-hours — a conservative annual average for the US, southern Europe and Australia (UK winters can fall below 1.5).

PV arrayReal harvest0–100% rechargeSun-days @ 4.5 PSHNet with load @ 50%
400 W 320 W 6.4 hrs 1.4 −505 W
800 W 640 W 3.2 hrs 0.7 −185 W
1,000 W 800 W 2.6 hrs 0.6 −25 W

A typical 800 W portable array refills the battery in about 3.2 hrs of strong sun, while maxing out the 1,000 W input cuts that to 2.6 hrs. To fully offset the 15,000 BTU RV Rooftop Air Conditioner (Dometic/Coleman) at a 50% duty cycle (825 W average) during daylight you need roughly 1,050 W of panels, which exceeds this unit's 1,000 W input limit — solar can slow the drain but not eliminate it.

5. Frequently Asked Questions

Can the Anker SOLIX F2000 (PowerHouse 767) run a 15,000 BTU RV Rooftop Air Conditioner (Dometic/Coleman)?

Yes. The Anker SOLIX F2000 (PowerHouse 767) delivers 2,400 W continuous and 3,600 W surge, covering the 15,000 BTU RV Rooftop Air Conditioner (Dometic/Coleman)'s 1,650 W running and 3,600 W start-up draw at 69% inverter utilization.

How long will the Anker SOLIX F2000 (PowerHouse 767) run a 15,000 BTU RV Rooftop Air Conditioner (Dometic/Coleman)?

With 2,048 Wh of capacity and 85% inverter efficiency, expect about 1.1 hrs of continuous operation and 2.1 hrs at a 50% duty cycle. Adding solar input during the day extends this further.

What breaker and wire size do I need to connect a 15,000 BTU RV Rooftop Air Conditioner (Dometic/Coleman) to the Anker SOLIX F2000 (PowerHouse 767)?

In the US, 1,650 W at 120 V is 13.8 A; applying the NEC 125% continuous-load rule gives 17.2 A, so use a 20 A breaker and 12 AWG copper for runs up to 25 ft (1.1% voltage drop). In 230 V markets the load draws 7.2 A, protected by a 10 A MCB on 1.5 mm² cable for runs up to 7.5 m. Receptacle: NEMA TT-30P (US) or BS 1363 13A / Schuko CEE 7/4 / AS/NZS 3112 10A (UK/EU/AU).

How long does it take to recharge the Anker SOLIX F2000 (PowerHouse 767) with solar panels?

With an 800 W array and an 80% real-world harvest factor, a full recharge takes about 3.2 hrs of peak sun (0.7 days at 4.5 peak-sun-hours). At its maximum 1,000 W solar input it drops to 2.6 hrs.

Methodology & safety note

Specifications come from manufacturer datasheets in our open dataset; ampacity and resistance values follow NEC Table 310.16 and Chapter 9 Table 8, and BS 7671 Appendix 4. Calculations assume copper conductors, 30 °C ambient and no bundling derating. Inverter-to-panel connections require a listed transfer switch or interlock to prevent back-feeding the grid. These results are an engineering estimate, not a substitute for a licensed electrician and local permit. See our methodology and safety disclaimer.

Status dots show the North American verdict: compatible, conditional, not compatible.

Other loads on the Anker SOLIX F2000 (PowerHouse 767)

All 50 loads on the Anker SOLIX F2000 (PowerHouse 767) →

Other power stations for the 15,000 BTU RV Rooftop Air Conditioner (Dometic/Coleman)

Compare every source for this load →

More RV & Marine on the Anker SOLIX F2000 (PowerHouse 767)