Can the myenergi Libbi (5kW Inverter + 5kWh Battery) Run a Vaillant aroTHERM Plus Air Source Heat Pump (7kW)?

Live runtime simulator, solar recharge calculator and NEC / IEC breaker & cable schematic for the myenergi Libbi (5kW Inverter + 5kWh Battery) (5,120 Wh) paired with the Vaillant aroTHERM Plus Air Source Heat Pump (7kW).

Configure your system

800 W
7.6 m (25 ft)
65%
Source outlets
Hardwired consumer unit (RCBO protected)
Load connection
Hardwired via DP isolator · IEC 60309 32A
Verified Hardware Match

Check current bundle pricing for the myenergi Libbi (5kW Inverter + 5kWh Battery) plus a changeover switch kit for this setup.

As an Amazon Associate, we earn from qualifying purchases.

Verified Compatible

myenergi Libbi (5kW Inverter + 5kWh Battery) handles 2,300 W continuous and 3,500 W surge with headroom.

2,700 W of continuous capacity left for other circuits.

Continuous load
46%
Runtime (no sun)
2.9 hrs
65% duty · 85% inverter eff.
Solar recharge
8.0 hrs
1.8 sun-days at 800 W
Min. copper wire
1.5 mm²
0.8% drop @ 7.6 m
Overcurrent device
10A MCB
10.0A load × 1.00 = 10.0A
Live schematic & breaker sizing diagram 230V AC • IEC 60364
SOLAR PV INPUT 800 W PV MC4 / XT60 · MPPT POWER SOURCE / INVERTER myenergi Libbi (5kW Inverter + 5kWh Battery) 5,120 Wh • 5,000 W 7,500 W surge • 120/240V 46% load 10A MCB 1.5 mm² Cu 10.0A @ 230V CONNECTED LOAD Vaillant aroTHERM Plus Air Source Heat Pump… 2,300 W running 3,500 W surge 230V load

Engineering report · reviewed against NEC 2026 & BS 7671:2018+A2

Engineering Breakdown: Running a Vaillant aroTHERM Plus Air Source Heat Pump (7kW) on the myenergi Libbi (5kW Inverter + 5kWh Battery)

UK/EU/AU: Verified Compatible 46% inverter utilization Sold in UK / EU / AU only

When pairing the myenergi Libbi (5kW Inverter + 5kWh Battery) (5,120 Wh LiFePO4 capacity, 5,000 W continuous, 7,500 W surge) with a Vaillant aroTHERM Plus Air Source Heat Pump (7kW) (2,300 W running, 3,500 W starting surge), the system operates at 46% of continuous inverter capacity on a 230 V UK/EU/AU circuit. At a 100% duty cycle and 85% inverter efficiency, a full battery delivers roughly 1.9 hrs of off-grid runtime. Wiring the connection over a 7.5 m run calls for a 10 A MCB and 1.5 mm² copper, terminated at a Hardwired via DP isolator · IEC 60309 32A connection.

1. Compatibility Verdict & Inverter Load Utilization

In UK/EU/AU 230 V mode the Vaillant aroTHERM Plus Air Source Heat Pump (7kW) loads the myenergi Libbi (5kW Inverter + 5kWh Battery)'s inverter to 46% of its 5,000 W continuous rating and 47% of its 7,500 W surge rating. Both figures are under the 80% sustained-load guideline, so this is a comfortable, verified match with 2,700 W of spare capacity for lights, a router or a refrigerator on the same unit.

CheckLoad requiresmyenergi Libbi providesUK/EU/AU
Continuous output 2,300 W 5,000 W Pass
Start-up surge 3,500 W 7,500 W Pass
Voltage 230 V 230 V Pass
Connection Hardwired via DP isolator · IEC 60309 32A Hardwired consumer unit (RCBO protected)

Air source heat pumps such as this one use inverter-driven compressors that ramp up gradually, so their start-up demand (3,500 W, 1.5× running) is far gentler than a fixed-speed air conditioner. The real challenge is energy, not surge: in a cold snap a heat pump can run for most of the day, and defrost cycles add short peaks. At 2,300 W, the myenergi Libbi (5kW Inverter + 5kWh Battery) would supply about 1.9 hrs of continuous heating from a full battery — so in practice batteries are used to shift cheap off-peak or solar energy into the evening, not to heat a home through a multi-day outage. UK installations are made under BS 7671 and MCS standards, and the local network operator (DNO) must be notified.

The myenergi Libbi (5kW Inverter + 5kWh Battery) is a UK smart home storage system, installed on a dedicated circuit from the consumer unit under BS 7671 and typically paired with a time-of-use tariff to charge overnight and discharge at peak. Backup operation for specific circuits depends on the installer fitting an EPS/backup switch.

2. Real-World Runtime by Duty Cycle

Nameplate capacity is not usable capacity. DC-to-AC conversion, battery management overhead and cell protection reduce the 5,120 Wh rating to about 4,352 Wh of deliverable AC energy (85% system efficiency). Duty cycle is the share of each hour the load actually draws its running power — thermostats, pressure switches and intermittent use all lower it.

Runtime (h) = (5,120 Wh × 0.85) ÷ (2,300 W × duty cycle)
Duty cycleAverage drawRuntime (no solar)Energy per 24 h
25% 575 W 7.6 hrs 13.8 kWh
50% 1,150 W 3.8 hrs 27.6 kWh
65% 1,495 W 2.9 hrs 35.9 kWh
100% 2,300 W 1.9 hrs 55.2 kWh

Even at a 50% duty cycle the battery lasts 3.8 hrs, so plan on solar, grid or generator recharging for anything longer than an evening outage.

3. BS 7671 / IEC 60364 Breaker & Cable Sizing

IEC-based codes size protection by design current rather than a blanket 125% multiplier: Ib ≤ In ≤ Iz. At 230 V the load draws 10.0 A, so a 10 A Type B/C MCB with RCD protection applies. In the UK, BS 7671 Section 722 additionally requires a dedicated circuit and Type A or Type B RCD for EV charge points.

One-way distanceMCBMin. cableVoltage drop
7.5 m (25 ft) 10 A 1.5 mm² 0.79%
15 m (49 ft) 10 A 1.5 mm² 1.58%
22.5 m (74 ft) 10 A 1.5 mm² 2.37%
30 m (98 ft) 10 A 2.5 mm² 1.93%

Moving the myenergi Libbi (5kW Inverter + 5kWh Battery) from 7.5 m to 30 m away forces the conductor up from 1.5 mm² to 2.5 mm² — park the unit as close to the load as ventilation and weather protection allow.

4. Solar Array Recharge Time Breakdown

The myenergi Libbi (5kW Inverter + 5kWh Battery) accepts up to 5,000 W of photovoltaic input. Real arrays rarely deliver nameplate output, so we apply an 80% harvest factor for MPPT conversion, cell temperature and soiling, and convert hours to days using 4.5 peak-sun-hours — a conservative annual average for the US, southern Europe and Australia (UK winters can fall below 1.5).

PV arrayReal harvest0–100% rechargeSun-days @ 4.5 PSHNet with load @ 50%
400 W 320 W 16.0 hrs 3.6 −830 W
800 W 640 W 8.0 hrs 1.8 −510 W
1,600 W 1,280 W 4.0 hrs 0.9 +130 W
3,000 W 2,400 W 2.1 hrs 0.5 +1,250 W
5,000 W 4,000 W 1.3 hrs 0.3 +2,850 W

A typical 800 W portable array refills the battery in about 8.0 hrs of strong sun, while maxing out the 5,000 W input cuts that to 1.3 hrs. To fully offset the Vaillant aroTHERM Plus Air Source Heat Pump (7kW) at a 50% duty cycle (1,150 W average) during daylight you need roughly 1,450 W of panels, which this unit can accept.

5. Frequently Asked Questions

Can the myenergi Libbi (5kW Inverter + 5kWh Battery) run a Vaillant aroTHERM Plus Air Source Heat Pump (7kW)?

Yes. The myenergi Libbi (5kW Inverter + 5kWh Battery) delivers 5,000 W continuous and 7,500 W surge, covering the Vaillant aroTHERM Plus Air Source Heat Pump (7kW)'s 2,300 W running and 3,500 W start-up draw at 46% inverter utilization.

How long will the myenergi Libbi (5kW Inverter + 5kWh Battery) run a Vaillant aroTHERM Plus Air Source Heat Pump (7kW)?

With 5,120 Wh of capacity and 85% inverter efficiency, expect about 1.9 hrs of continuous operation and 3.8 hrs at a 50% duty cycle. Adding solar input during the day extends this further.

What breaker and wire size do I need to connect a Vaillant aroTHERM Plus Air Source Heat Pump (7kW) to the myenergi Libbi (5kW Inverter + 5kWh Battery)?

At 230 V the load draws 10.0 A. Under BS 7671 / IEC 60364 the protective device must be at least the design current (Ib ≤ In ≤ Iz), so use a 10 A MCB with RCD protection on 1.5 mm² copper cable for runs up to 7.5 m (0.8% voltage drop). Connection: Hardwired via DP isolator · IEC 60309 32A.

How long does it take to recharge the myenergi Libbi (5kW Inverter + 5kWh Battery) with solar panels?

With an 800 W array and an 80% real-world harvest factor, a full recharge takes about 8.0 hrs of peak sun (1.8 days at 4.5 peak-sun-hours). At its maximum 5,000 W solar input it drops to 1.3 hrs.

Methodology & safety note

Specifications come from manufacturer datasheets in our open dataset; ampacity and resistance values follow NEC Table 310.16 and Chapter 9 Table 8, and BS 7671 Appendix 4. Calculations assume copper conductors, 30 °C ambient and no bundling derating. Inverter-to-panel connections require a listed transfer switch or interlock to prevent back-feeding the grid. These results are an engineering estimate, not a substitute for a licensed electrician and local permit. See our methodology and safety disclaimer.

Status dots show the UK/EU/AU verdict: compatible, conditional, not compatible.

Other loads on the myenergi Libbi (5kW Inverter + 5kWh Battery)

All 50 loads on the myenergi Libbi (5kW Inverter + 5kWh Battery) →

Other power stations for the Vaillant aroTHERM Plus Air Source Heat Pump (7kW)

Compare every source for this load →