Engineering report · reviewed against NEC 2026 & BS 7671:2018+A2
Engineering Breakdown: Running a Hyundai Ioniq 5 (24A Level 2 Portable EVSE) on the Sungrow SH10RS Hybrid Inverter + Battery
When pairing the Sungrow SH10RS Hybrid Inverter + Battery (9,600 Wh LiFePO4 capacity, 10,000 W continuous, 15,000 W surge) with a Hyundai Ioniq 5 (24A Level 2 Portable EVSE) (5,760 W running, 5,760 W starting surge), the system operates at 55% of continuous inverter capacity on a 230 V UK/EU/AU circuit. At a 100% duty cycle and 85% inverter efficiency, a full battery delivers roughly 1.5 hrs of off-grid runtime. Wiring the connection over a 7.5 m run calls for a 25 A MCB and 2.5 mm² copper, terminated at a Type 2 EVSE · IEC 60309 32A Commando connection.
1. Compatibility Verdict & Inverter Load Utilization
In UK/EU/AU 230 V mode the Hyundai Ioniq 5 (24A Level 2 Portable EVSE) loads the Sungrow SH10RS Hybrid Inverter + Battery's inverter to 55% of its 10,000 W continuous rating and 37% of its 15,000 W surge rating. Both figures are under the 80% sustained-load guideline, so this is a comfortable, verified match with 4,480 W of spare capacity for lights, a router or a refrigerator on the same unit.
| Check | Load requires | Sungrow SH10RS Hybrid Inverter + Battery provides | UK/EU/AU |
|---|---|---|---|
| Continuous output | 5,520 W | 10,000 W | Pass |
| Start-up surge | 5,520 W | 15,000 W | Pass |
| Voltage | 230 V | 230 V | Pass |
| Connection | Type 2 EVSE · IEC 60309 32A Commando | Hardwired consumer unit (RCBO protected) |
An EVSE is a constant-current device: the vehicle draws exactly the current advertised by the J1772/NACS pilot signal, so the 5,760 W figure is both the running load and the start-up load — there is no motor inrush. That makes the calculation unusually clean. If you want to stay under the 80% sustained-load guideline, set the charge current in the vehicle app to 33 A or less, which keeps the Sungrow SH10RS Hybrid Inverter + Battery at roughly 7,920 W. A full battery delivers about 7.3 kWh into the pack after inverter and on-board charger losses, worth roughly 26 miles (41 km) of driving at 3.5 mi/kWh.
The Sungrow SH10RS Hybrid Inverter + Battery is a grid-tied hybrid inverter with battery storage, widely installed across Australia and New Zealand under AS/NZS 4777 and AS/NZS 3000. Backup to essential circuits requires a dedicated backup output and changeover arrangement.
2. Real-World Runtime by Duty Cycle
Nameplate capacity is not usable capacity. DC-to-AC conversion, battery management overhead and cell protection reduce the 9,600 Wh rating to about 8,160 Wh of deliverable AC energy (85% system efficiency). EV charging runs at a fixed current, so the 100% row is the realistic figure; lower rows apply only if you schedule charging in intervals.
| Duty cycle | Average draw | Runtime (no solar) | Energy per 24 h |
|---|---|---|---|
| 25% | 1,380 W | 5.9 hrs | 33.1 kWh |
| 50% | 2,760 W | 3.0 hrs | 66.2 kWh |
| 65% | 3,588 W | 2.3 hrs | 86.1 kWh |
| 100% | 5,520 W | 1.5 hrs | 132.5 kWh |
Even at a 50% duty cycle the battery lasts 3.0 hrs, so plan on solar, grid or generator recharging for anything longer than an evening outage.
3. BS 7671 / IEC 60364 Breaker & Cable Sizing
IEC-based codes size protection by design current rather than a blanket 125% multiplier: Ib ≤ In ≤ Iz. At 230 V the load draws 24.0 A (the EVSE's 24 A pilot current at 230 V), so a 25 A Type B/C MCB with RCD protection applies. In the UK, BS 7671 Section 722 additionally requires a dedicated circuit and Type A or Type B RCD for EV charge points.
| One-way distance | MCB | Min. cable | Voltage drop |
|---|---|---|---|
| 7.5 m (25 ft) | 25 A | 2.5 mm² | 1.16% |
| 15 m (49 ft) | 25 A | 2.5 mm² | 2.32% |
| 22.5 m (74 ft) | 25 A | 4.0 mm² | 2.16% |
| 30 m (98 ft) | 25 A | 4.0 mm² | 2.89% |
Moving the Sungrow SH10RS Hybrid Inverter + Battery from 7.5 m to 30 m away forces the conductor up from 2.5 mm² to 4.0 mm² — park the unit as close to the load as ventilation and weather protection allow.
4. Solar Array Recharge Time Breakdown
The Sungrow SH10RS Hybrid Inverter + Battery accepts up to 15,000 W of photovoltaic input. Real arrays rarely deliver nameplate output, so we apply an 80% harvest factor for MPPT conversion, cell temperature and soiling, and convert hours to days using 4.5 peak-sun-hours — a conservative annual average for the US, southern Europe and Australia (UK winters can fall below 1.5).
| PV array | Real harvest | 0–100% recharge | Sun-days @ 4.5 PSH | Net with load @ 50% |
|---|---|---|---|---|
| 1,600 W | 1,280 W | 7.5 hrs | 1.7 | −1,480 W |
| 3,000 W | 2,400 W | 4.0 hrs | 0.9 | −360 W |
| 6,000 W | 4,800 W | 2.0 hrs | 0.4 | +2,040 W |
| 12,000 W | 9,600 W | 1.0 hrs | 0.2 | +6,840 W |
| 15,000 W | 12,000 W | 48 min | 0.2 | +9,240 W |
A typical 800 W portable array refills the battery in about 15.0 hrs of strong sun, while maxing out the 15,000 W input cuts that to 48 min. To fully offset the Hyundai Ioniq 5 (24A Level 2 Portable EVSE) at a 50% duty cycle (2,760 W average) during daylight you need roughly 3,450 W of panels, which this unit can accept.
5. Frequently Asked Questions
Can the Sungrow SH10RS Hybrid Inverter + Battery run a Hyundai Ioniq 5 (24A Level 2 Portable EVSE)?
Yes. The Sungrow SH10RS Hybrid Inverter + Battery delivers 10,000 W continuous and 15,000 W surge, covering the Hyundai Ioniq 5 (24A Level 2 Portable EVSE)'s 5,520 W running and 5,520 W start-up draw at 55% inverter utilization.
How many miles of range can the Sungrow SH10RS Hybrid Inverter + Battery add to a Hyundai Ioniq 5?
A full 9,600 Wh charge delivers about 7.3 kWh to the vehicle battery after inverter (85%) and on-board charger (90%) losses — roughly 26 miles at 3.5 mi/kWh. At the full 5,520 W charge rate that takes 1.5 hrs.
What breaker and wire size do I need to connect a Hyundai Ioniq 5 (24A Level 2 Portable EVSE) to the Sungrow SH10RS Hybrid Inverter + Battery?
At 230 V the load draws 24.0 A. Under BS 7671 / IEC 60364 the protective device must be at least the design current (Ib ≤ In ≤ Iz), so use a 25 A MCB with RCD protection on 2.5 mm² copper cable for runs up to 7.5 m (1.2% voltage drop). Connection: Type 2 EVSE · IEC 60309 32A Commando.
How long does it take to recharge the Sungrow SH10RS Hybrid Inverter + Battery with solar panels?
With an 800 W array and an 80% real-world harvest factor, a full recharge takes about 15.0 hrs of peak sun (3.3 days at 4.5 peak-sun-hours). At its maximum 15,000 W solar input it drops to 48 min.
Methodology & safety note
Specifications come from manufacturer datasheets in our open dataset; ampacity and resistance values follow NEC Table 310.16 and Chapter 9 Table 8, and BS 7671 Appendix 4. Calculations assume copper conductors, 30 °C ambient and no bundling derating. Inverter-to-panel connections require a listed transfer switch or interlock to prevent back-feeding the grid. These results are an engineering estimate, not a substitute for a licensed electrician and local permit. See our methodology and safety disclaimer.